HID® Proximity ProxPoint® Plus 6005
- 
      
        
          
        
      
      HID's ProxPoint Plus reader combines multiple configuration options with an attractive, inconspicuous design and economical price. Its secure potted electronics are ideal for both indoor and outdoor applications. - Small sized, low cost reader features a beeper and multicolor LED which can be host and/or locally controlled. 
- Potted reader suitable for indoor or outdoor use. 
- 18" (45 cm) wire pigtail standard; consult factory for 9' (2.7 m) pigtail available by special order. 
- Classic Series covers available in black, gray, white or beige. Designer Series covers available in black or gray. 
 
- 
      
        
      
      - Features a beeper and multicolor LED which can be host and/ or locally controlled. 
- Enables various beeper and LED configurations, depending on individual site requirements. 
- Can read HID cards with formats up to 85 bits. 
- Designed for mounting directly onto metal with no change in read range performance. 
- Available with either Wiegand or Clock-and-Data (magnetic stripe data) output. 
- Compatible with all standard access control systems. 
- Aesthetic design available in two cover designs and in four colors to match any decor. 
- Includes multilingual installation manual. 
 
- 
      
        
      
      Typical maximum* read range: - ProxCard® II Card - up to 3" (7.6 cm) 
- ISOProx® II card - up to 2.5" (6.35 cm) 
- DuoProx® II Card - up to 2.5" (6.35 cm) 
- Smart ISOProx®/DuoProx® II Cards - up to 2.5" (6.35 cm) 
- Proximity & MIFARE® Card - up to 2.5" (6.35 cm) 
- ProxCard Plus® Card - up to 1.0" (2.5 cm) 
- ProxKey® II Keyfob - up to 1.5" (3.8 cm) 
- MicroProx® Tag - up to 2" (5.1 cm) 
 *Depending on local installation conditions. 
 Dimensions
 3.135" x 1.720" x 0.660" (7.96 x 4.37 x 1.68 cm)
 Power Supply:- 5-16 VDC 
- Linear power supplies are recommended. 
 Maximum Current Requirements: - Current (DC) 
- Average 30 mA, Peak 75 mA 
 Operating Temperature 
 -22º to 150º F (-30º to 65º C)
 Operating Humidity
 0-95% relative humidity noncondensing
 Weight
 2.7 oz. (75 gm)Current Requirements 
 20mA avg / 75mA peak at 12VDCCable Distance: - Wiegand or Clock-and-Data interface: 
- 500 feet (150 m) 
- Recommended cable is ALPHA 1295 (22 AWG) 5 conductor stranded with overall shield or equivalent. 
 Certifications: - Canada/UL 294 Listed 
- FCC Certification, United States 
- Canada Certification 
- EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety) 
- Fifteen EU Countries under the R&TTE Directive (EN 300 330 - SRD, and ETS 300 683 - EMC) 
- CE Mark 
- Australia C-Tick, New Zealand 
- Taiwan, China 
 