HID® Proximity ProxPro® II 5455

  • HID's ProxPro II proximity reader for access control combines performance, reliability, and ease of installation into a two-piece, weatherproof potted enclosure. International users will appreciate the multilingual installation manual, lower voltage requirement and flexible mounting options.

    • Ideal for medium-range applications.

    • Available with Wiegand or Clock-and-Data interface.

    • Optional glass mount kit available for mounting the reader behind glass.

    • Potted reader suitable for indoor or outdoor use.

    • Available in black, white, gray or beige.

    • 18" (45 cm) wire pigtail standard; consult factory for 9' (2.7 m) pigtail available by special order.

    • Two-piece reader design allows for easy installation.

    • Available with a Wiegand or Clock-and-Data interface.

    • Provides high reliability, consistent read range and low power consumption.

    • Features include multicolor LED and internal control or host control of the LED and beeper.

    • Mounts directly on metal with minimal impact on the read range performance. Optional kit enables mounting behind glass.

    • Compare features of the ProxPro II to the original ProxPro reader

  • Typical Maximum Read Range:

    • ProxCard® II Card - up to 9" (22 cm)

    • ISOProx® II Card - up to 8" (20 cm)

    • DuoProx® II Card - up to 8" (20 cm)

    • Smart ISOProx® Card - up to 8" (20 cm)

    • Smart DuoProx® Card - up to 8" (20 cm)

    • HID Proximity and MIFARE® card - up to 8" (20 cm)

    • ProxCard® Plus Card - up to 4" (10 cm)

    • ProxKey® II Keyfob - up to 4" (10 cm)

    • MicroProx® Tag - up to 4" (11 cm)

    *Depending on local installation conditions.

    Dimensions
    5.00" x 5.00" x 1.00" (12.7 x 12.7 x 2.54 cm)

    Power supply:

    • 5-16 VDC

    • Linear power supplies are recommended.

    Cable Distance:

    • Wiegand interface: 500 feet (150 m)

    • Clock-and-Data interface: 50 feet (15 m)

    • Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper control.

    Current Requirements:

    • Average: 25 mA at 12 VDC

    • Peak: 125 mA at 12 VDC

    Operating Temperature
    -22º to 150º F (-30º to 65º C)

    Operating Humidity
    0-95% relative humidity non-condensing

    Weight
    13.6 oz. (385 g)

    Certifications:

    • Canada/UL 294 Listed

    • FCC Certification, United States

    • Canada Certification

    • CE Mark

    • EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety)

    • Fifteen EU Countries under the R&TTE Directive (EN300 330 - SRD, and ETS 300 683 - EMC)

    • Australia C-Tick (pending)

    • New Zealand (pending)

    • Taiwan (pending)